TSP P4000 Pump, AS3000 Autosampler, UV1000 Detector
| Listed Under TSP HPLC |
TSP P4000 Pump, AS3000 Autosampler, UV1000 Detector
$8,900
This system is in good condition and comes fully tested at GenTech.
Includes:
- P4000 Quaternary Gradient Pump
- UV1000 Dual Wavelength UV/Vis Programmable Detector
- AS3000 Autosampler
- NINETY (90) DAY WARRANTY.
Optional – Clarity-Lite Data Acquisition Software – allows acquisition, integration and display of one detector channel from a GC or LC. Note: Computer and Cables to connect to your system are not included.

TSP P4000 Pump, AS3000 Autosampler, UV1000 Detector
P4000 Specifications:
- Pump Design: Dual in-line piston, pulseless design. Micro-stepped motor control. Floating piston bayonet-mounted heads. Patented ceramic check valves.
- Flow accuracy: ±0.5% at 1 ml/min with water, after liquid end calibration.
- Flow precision: <0.2% RSD
- Flow Range: 0.01 to 10 ml/min standard. Settable in 0.01 ml/min increments.
- Composition Repeatability: 0.2% RSD
- Gradient Linearity: ±0.5% from 10-90% composition
- Maximum Pressure: 6000 psi, 420 bar, 42MPa with standard heads
- Wetted Surfaces: Stainless steel or PEEK, titanium, ceramic, sapphire, Teflon, Tefzel, and polyethylene
- Pressure Pulsation: <2% amplitude; <1% typical at 1ml/min water or methanol at >500 psi
- Delay Volume: <0.6ml
- Compressibility Compensation: Automatic
- Shutdown File: Protected in non-volatile memory
- Flow Stability Test: Pump flow diagnostic to verify proper pump performance
- Diagnostics: Diagnostic tests to verify proper electrical and mechanical operation
- Communications: Hardwire external events connector. Run and Stop remote inputs; Ready, Run, Timed Event and Analog Pressure outputs. SCM400 degas communication port.
-
Ambient Environment: 10-40°C, 5-95% relative humidity, noncondensing.
UV1000 Specifications:
- Wavelength Ranges: D2 lamp: 190 to 380 nm, W lamp: 366 to 800 nm
- Lamp: D2
- Wavelength Accuracy: ± 1.0 nm
- Wavelength Precision: <0.01 nm
- Bandwidth: 6 nm
- Range Selections: 3.0, 2.0, 1.0, 0.5, 0.2, 0.1, 0.05, 0.02, 0.01, 0.005, 0.002, 0.001, 0.0005 AUFS
- Absorbance Range: 0.0005 to 3.0 AUFS
- Absorance Linearity @ 254 nm: 3.0 AUFS
- Communications:
- Romote Inputs: Run, Stop, and Zero
- Romote Output: Ready
- Vial capacity:
- 120 vials in three removable trays
- 105 vials with tray temperature control - Variable-Volume:
- Injection Precision: <0.5 % RSD @ 10 pL or greater
- Injection Volume: 0.1 – 100 pL injection standard (250 uL syringe) up to 1000 uL injections with larger loops and syringes - Fixed-Loop:
- Injection Precision: <0.5% RSD @ 10 uL or greater
- Injection Volume: 20 uL standard (250 uL syringe) 1000 uL injections with larger loops and syringes - Sample Carryover:
- <0.0 I% at 300 gL flush volume
- 5 mL flush volumes can be set - Minimum Sample Volume: 1 uL can be injected from 5 uL with an end-port needle
- Needle Height: Programmable in 0.1 mm increments
- Method Files: Protected in non-volatile memory
- Communications
- Remote Inputs: Pump Ready, Inject Hold
- Outputs Pump Stop, Autosampler Ready, Inject, Gradient Start, Four timed-event outputs
- SpectraNETIRS-232 port - Ambient Environment: 10° – 40°C, 5 – 95% relative humidity
- Dimensions: 37cm x 41 cmx 51 cm (HxWxD)