Shimadzu GC-2010 with Single Wide Bore
| Listed Under Shimadzu GC |
Shimadzu GC-2010 with Single Wide Bore
$3,800*
System Includes:
- Single Wide Bore
- Single Flame Ionization Detector (FID)
- Fast Oven Cooling Option
- Automatic Pressure Control (APC)
- 110V/60Hz
- User Manual
ONE (1) YEAR WARRANTY Available
Available Options:
- AOC 20i Autosamplerwith 150-Sample Tray – $2,500
- Single Wide Bore- $2,250
- Single Split/Splitless Injector – $5,900
- Single Flame Ionization Detector (FID) – $2,250
- Clarity-Lite Data Acquisition Software – allows acquisition, integration and display of one detector channel – $2,300
Note: Computer and Cables to connect to your system are not included. - Shimadzu LabSolutions for GC Data System – $7500 (Includes computer)
- Shimadzu 2010 GC Starter Kit – $998
*All prices are in U.S. dollars and do not include shipping, handling and installation.

Shimadzu GC-2010 with autosampler


| Column Oven | |
| Temperature Range | (Ambient + 4°C) ~ 450°C (using LCO2 gas: -50°C-450°C) |
| Inner Dimensions and Volume | 280 (W) x 280 (H) x 175 (D) mm, 13.7L |
| Temperature accuracy | ±1% of the set temperature in Kelvin unit (calibration at 0.01°C increments) |
| Temperature Variation Coefficient | 0.01°C/°C |
| Temperature Program Steps | Up to 20 (cooling program possible) |
| Programmed rate setting range | -250°C ~ 250°C/min |
| Total time for all steps | 9999.99 minutes max. |
| Injection Ports | |
| Temperature Range | Up to 400°C |
| Heating Settings | 1°C steps |
| No. of units installed simultaneously | Up to 3 units |
| Sample injection unit types | Split/splitless injection is standard Direct (without split) injection unit (option) On-column/PTV (programmable temperature vaporizer)injection unit (option) |
| low Control Unit | |
| Advanced Flow Controller (AFC) | |
| Split/splitles injection mode and direct injection mode | Pressure range: 0-970kPa |
| Programmable Steps | 7 (Negative pressure step is available) |
| Programmed Rate Setting Range | -400 ~ 400kPa/min |
| Split Ratio Range | 0 – 9999.9 |
| Mass Flow Rate Setting Range | 0 – 1200mL/min |
| Constant Linear Velocity | Maintains optimum separation at all times |
| Available Optional Accessories | |
| AOC-20i Auto Injector | Direct injection, PTV/LVI, 1 – 250 uL syringes, ambient headspace |
| AOC-20s Auto Sampler | 150 1.5mL vials or 96 4mL vials and barcode reader |
| Leap Combi-Pal Autosampler | SPME, headspace and micro-titer plate sampling capability |
| PY2020D Pyrolyzer | Single or double shot includes autosampler |
| Detectors | |
| Four detectors can be installed simultaneously and individually temperature controlled. Detector gas is electronically controlled by APC (Advanced Pressure Control) | |
| Detector Type(s) | FID, TCD, ECD, FPD, FTD |
| Flame Ionization Detector (FID) | |
| Temperature Range | 450°C max. |
| Minimum detected quantity | 3pgC/s (Dodecane) |
| Dynamic Range | 107 |
| Thermal Conductivity Detector (TCD) | |
| Temperature Range | 400°C max. |
| Dynamic Range | 105 |
| Sensitivity | 20,000 mV – mL/mg (Decane) |
| Electron Capture Detector (ECD) | |
| Temperature Range | 350°C max. |
| Minimum detected quantity | 8fg/s |
| Dynamic Range | 104 |
| Flame Photometric Detector (FPD) | |
| Temperature Range | 350°C max. |
| Dynamic Range | P: 104 S: 103 |
| Minimum detected quantity | P: 0.2pgP/s (tributyl phosphate) S: 4pgS/s (dodecane thiol) |
| Flame Thermionic Detector (FTD) (Two types, one for capillary and one for packed. The specifications are the same.) |
|
| Temperature Range | 450°C max. |
| Dynamic Range | N: 104 P: 104 |
| Minimum detected quantity | N: 0.2pgN/s (azobenzene) P: 0.03pgP/s (malathion) |
| Maximum of 2 detectors to keep instrument performance | |
| Dimensions, Weight, Power Requirements (GC main unit) | |
| Dimensions | 515 (W) x 440 (H) x 530 (D) mm |
| Weight | 30 kg (FID model) |
| Power Requirements | AC100V/120V 230V 1800VA (Normal oven type) or 2600VA (High power oven type), 50/60Hz |