Shimadzu GC-2010 with Single Split/Splitless Injector

Listed Under Shimadzu GC

Shimadzu GC-2010 with Single Split/Splitless Injector
$8,400*

System Includes:

  • Single Split/Splitless Injector
  • Single Flame Ionization Detector (FID)
  • Fast Oven Cooling Option
  • Automatic Pressure Control (APC)
  • 110V/60Hz
  • User Manual
  • ONE (1) YEAR WARRANTY

Available Options:

  • AOC 20i Autosampler with 150-Sample Tray – $2,500
  • Shimadzu 2010 GC Solutions Data System- $5,550
    Includes computer, monitor, and software.
  • Single Wide Bore$2,250
  • Single Split/Splitless Injector – $5,900
  • Single Flame Ionization Detector (FID) – $2,250
  • Single Channel PeakSimple Software - $1,495
  • Shimadzu 2010 GC Starter Kit$988
2010

Shimadzu GC-2010 with autosampler

shimadzu-2010-data-FID

Specifications

Column Oven
Temperature Range (Ambient + 4°C) ~ 450°C (using LCO2 gas: -50°C – 450°C)
Inner Dimensions and Volume 280 (W) x 280 (H) x 175 (D) mm, 13.7L
Temperature accuracy ±1% of the set temperature in Kelvin unit (calibration at 0.01°C increments)
Temperature Variation Coefficient 0.01°C/°C
Temperature Program Steps Up to 20 (cooling program possible)
Programmed rate setting range -250°C ~ 250°C/min
Total time for all steps 9999.99 minutes max.
Injection Ports
Temperature Range Up to 400°C
Heating Settings 1°C steps
No. of units installed simultaneously Up to 3 units
Sample injection unit types Split/splitless injection is standard
Direct (without split) injection unit (option)
On-column/PTV (programmable temperature vaporizer)injection unit (option)
Flow Control Unit
Advanced Flow Controller (AFC)
Split/splitles injection mode and direct injection mode Pressure range: 0-970kPa
Programmable Steps 7 (Negative pressure step is available)
Programmed Rate Setting Range -400 ~ 400kPa/min
Split Ratio Range 0 – 9999.9
Mass Flow Rate Setting Range 0 – 1200mL/min
Constant Linear Velocity Maintains optimum separation at all times
Available Optional Accessories
AOC-20i Auto Injector Direct injection, PTV/LVI, 1 – 250 uL syringes, ambient headspace
AOC-20s Auto Sampler 150 1.5mL vials or 96 4mL vials and barcode reader
Leap Combi-Pal Autosampler SPME, headspace and micro-titer plate sampling capability
PY2020D Pyrolyzer Single or double shot includes autosampler
Detectors
Four detectors can be installed simultaneously and individually temperature controlled. Detector gas is electronically controlled by APC (Advanced Pressure Control)
Detector Type(s) FID, TCD, ECD, FPD, FTD
Flame Ionization Detector (FID)
Temperature Range 450°C max.
Minimum detected quantity 3pgC/s (Dodecane)
Dynamic Range 107
Thermal Conductivity Detector (TCD)
Temperature Range 400°C max.
Dynamic Range 105
Sensitivity 20,000 mV – mL/mg (Decane)
Electron Capture Detector (ECD)
Temperature Range 350°C max.
Minimum detected quantity 8fg/s
Dynamic Range 104
Flame Photometric Detector (FPD)
Temperature Range 350°C max.
Dynamic Range P: 104
S: 103
Minimum detected quantity P: 0.2pgP/s (tributyl phosphate)
S: 4pgS/s (dodecane thiol)
Flame Thermionic Detector (FTD)
(Two types, one for capillary and one for packed. The specifications are the same.)
Temperature Range 450°C max.
Dynamic Range N: 104
P: 104
Minimum detected quantity N: 0.2pgN/s (azobenzene)
P: 0.03pgP/s (malathion)
Maximum of 2 detectors to keep instrument performance
Dimensions, Weight, Power Requirements (GC main unit)
Dimensions 515 (W) x 440 (H) x 530 (D) mm
Weight 30 kg (FID model)
Power Requirements AC100V/120V 230V
1800VA (Normal oven type) or
2600VA (High power oven type), 50/60Hz