AP/MALDI Ion Source for Finnigan Mass Spectrometers

Listed Under MS Accessories           
  • Share/Bookmark

AP/MALDI Ion Source for Finnigan Mass Spectrometers*

Call for Quote

The AP/MALDI ion source comes standard with:

  • Ion source head for a 96-spot sample plate
  • two 96-spot sample plates
  • control unit for N2 laser operations & sample plate manipulation
  • CCD camera and imaging system
  • external laser spot position adjustment
  • electrical and optical cables
  • control software

Includes NINETY (90) DAY WARRANTY. Service and Operation Training available at GenTech Scientific or in your lab.

*All prices are in U.S. dollars and do not include shipping, handling and installation.

AP_Maldi Ion Source

AP/MALDI Ion Source for Finnigan

Mass Spectrometers Models – Price
LTQ Advantage and DECA XP AP/MALDI PDF 112 – $58,695
AP/MALDI PDF+ 113 – $68,695
LTQ, LTQ-Orbitrap, LTQ-FT, LCQ Deca XP MAX, and LCQ Advantage MAX
AP/MALDI PDF 132 – $58,695
AP/MALDI PDF+ 133 – $68,695
LCQ Deca XP, LCQ Deca XP Plus, and LCQ Advantage
AP/MALDI 121 – $51,495
AP/MALDI PDF 122 – $56,695
AP/MALDI PDF+ 123 – $66,695
LCQ Classic, Duo and Deca
AP/MALDI 111 – $51,495

Key Benefits of AP/MALDI:

  • Fast analyses – AP/MALDI operates at atmospheric pressure; no pump down time is needed. Sample plates can be loaded in seconds.
  • High sensitivity – Low-femtomole to attomole sample amounts spotted on the sample plate can be detected.
  • Searchable MS/MS spectra – AP/MALDI generates MS and MS/MS data quickly and easily. Allows database searching for protein identification. AP/MALDI MS/MS data is much easier to acquire than MALDI-TOFs post-source decay data.
  • Complementary data – The MALDI capability, on a typically ESI instrument, allows analysis of singly charged ions and when combined with an ion trap allows MSn. Generation of MALDI data complements multiply-charged data from ESI.
  • Rapidly interchangeable – The design of the AP/MALDI source is similar to that of the ESI source so changing sources is simple. Switching to AP/MALDI only takes minutes.
  • Excellent reliability – With new pulsed dynamic focusing (PDF) technology which has been added to AP/MALDI systems, laser misalignments are eliminated and a robust stable operation is achieved. All AP/MALDI systems are delivered pre-configured/aligned, and go through rigorous quality testing.
  • Great Value – The most inexpensive way to get MALDI capability in the lab. Adding AP/MALDI to an existing instrument is far less expensive than purchasing a new Q-TOF or TOF-TOF instrument. And AP/MALDI provides searchable MS and MS/MS spectra that answer many of the same questions.

AP MALDI SOURCEAP MALDI SOURCE CONTROL BOX

AP/MALDI PDF+
High repetition rate all-solid-state Nd:YAG laser

A 3rd Generation AP/MALDI

AP MALDI control box

Hardware

  • Output energy: 200 µJ/pulse
  • Wavelength: 355 nm
  • Frequency: up to 200 Hz
  • Pulse duration 3-5 nsec
  • Attenuation: 0-100% in 2-3%
  • increments (via software)
  • Lifetime: 1 billion pulses

Advantages

  • High throughput applications
  • Better ion signal
  • Lower lifetime ownership cost