AP/MALDI Ion Source for Finnigan Mass Spectrometers
Listed Under MS AccessoriesAP/MALDI Ion Source for Finnigan Mass Spectrometers*
Call for Quote
The AP/MALDI ion source comes standard with:
- Ion source head for a 96-spot sample plate
- two 96-spot sample plates
- control unit for N2 laser operations & sample plate manipulation
- CCD camera and imaging system
- external laser spot position adjustment
- electrical and optical cables
- control software
Includes NINETY (90) DAY WARRANTY. Service and Operation Training available at GenTech Scientific or in your lab.
*All prices are in U.S. dollars and do not include shipping, handling and installation.

AP/MALDI Ion Source for Finnigan
| Mass Spectrometers | Models – Price |
| LTQ Advantage and DECA XP | AP/MALDI PDF 112 – $58,695 AP/MALDI PDF+ 113 – $68,695 |
| LTQ, LTQ-Orbitrap, LTQ-FT, LCQ Deca XP MAX, and LCQ Advantage MAX |
AP/MALDI PDF 132 – $58,695 AP/MALDI PDF+ 133 – $68,695 |
| LCQ Deca XP, LCQ Deca XP Plus, and LCQ Advantage |
AP/MALDI 121 – $51,495 AP/MALDI PDF 122 – $56,695 AP/MALDI PDF+ 123 – $66,695 |
| LCQ Classic, Duo and Deca |
AP/MALDI 111 – $51,495 |
Key Benefits of AP/MALDI:
- Fast analyses – AP/MALDI operates at atmospheric pressure; no pump down time is needed. Sample plates can be loaded in seconds.
- High sensitivity – Low-femtomole to attomole sample amounts spotted on the sample plate can be detected.
- Searchable MS/MS spectra – AP/MALDI generates MS and MS/MS data quickly and easily. Allows database searching for protein identification. AP/MALDI MS/MS data is much easier to acquire than MALDI-TOFs post-source decay data.
- Complementary data – The MALDI capability, on a typically ESI instrument, allows analysis of singly charged ions and when combined with an ion trap allows MSn. Generation of MALDI data complements multiply-charged data from ESI.
- Rapidly interchangeable – The design of the AP/MALDI source is similar to that of the ESI source so changing sources is simple. Switching to AP/MALDI only takes minutes.
- Excellent reliability – With new pulsed dynamic focusing (PDF) technology which has been added to AP/MALDI systems, laser misalignments are eliminated and a robust stable operation is achieved. All AP/MALDI systems are delivered pre-configured/aligned, and go through rigorous quality testing.
- Great Value – The most inexpensive way to get MALDI capability in the lab. Adding AP/MALDI to an existing instrument is far less expensive than purchasing a new Q-TOF or TOF-TOF instrument. And AP/MALDI provides searchable MS and MS/MS spectra that answer many of the same questions.
AP/MALDI PDF+
High repetition rate all-solid-state Nd:YAG laser
A 3rd Generation AP/MALDI
Hardware
- Output energy: 200 µJ/pulse
- Wavelength: 355 nm
- Frequency: up to 200 Hz
- Pulse duration 3-5 nsec
- Attenuation: 0-100% in 2-3%
- increments (via software)
- Lifetime: 1 billion pulses
Advantages
- High throughput applications
- Better ion signal
- Lower lifetime ownership cost