| TSP
P4000 Pump, AS3000 Autosampler, UV1000 Detector and Software
$6,500*
This
system is in good condition and tested at GenTech. Includes
P4000 Quaternary Gradient Pump, UV1000 UV/Vis
Programmable Detector, AS3000 Autosampler and Data
System. This system includes SIX
(6) MONTH WARRANTY.
SRI
Model 203 Single Channel Chromatography Data System**
includes PeakSimple Software to run with Windows 95,
98 Me, XP, and Windows NT 4.0, allows acquisition, integration
and display of one detector channel from a GC or LC. Includes
two independent timebases, two 0-5VDC DACs, two remote start
inputs and built-in AC power supply. Also includes 24-bit
serially interfaced acquisition hardware, manuals, FREE lifetime
software upgrades and TWO (2) YEAR
WARRANTY.
Does
not include computer - requires Win 95 or newer.
**GenTech
is a distributor of new SRI instruments.
*All
prices are in U.S. dollars and do not include shipping, handling
and installation. International
Cooperating Organizations
|
|
|
P4000
Specifications:
Back
to top
UV1000
Specifications:
- Wavelength
Ranges: D2 lamp: 190 to 380 nm, W lamp: 366 to 800 nm
- Lamp:
D2
- Wavelength
Accuracy: ± 1.0 nm
- Wavelength
Precision: <0.01 nm
- Bandwidth:
6 nm
- Range
Selections: 3.0, 2.0, 1.0, 0.5, 0.2, 0.1, 0.05, 0.02, 0.01,
0.005, 0.002, 0.001, 0.0005 AUFS
- Absorbance
Range: 0.0005 to 3.0 AUFS
- Absorance
Linearity @ 254 nm: 3.0
AUFS
- Communications:
- Romote Inputs: Run, Stop, and Zero
- Romote Output: Ready
AS3000
Specifications:
- Vial
capacity:
- 120 vials in three removable trays
- 105 vials with tray temperature control
- Variable-Volume:
- Injection Precision: <0.5 % RSD @ 10 pL or greater
- Injection Volume: 0.1 - 100 pL injection standard (250 uL syringe)
up to 1000 uL injections with larger loops and syringes
- Fixed-Loop:
- Injection Precision: <0.5% RSD @ 10 uL or greater
- Injection Volume: 20 uL standard (250 uL syringe) 1000 uL injections
with larger loops and syringes
- Sample Carryover:
- <0.0 I% at 300 gL flush volume
- 5 mL flush volumes can be set
- Minimum
Sample Volume: 1 uL can be injected from 5 uL with an end-port
needle
- Needle
Height: Programmable in 0.1 mm increments
- Method
Files: Protected in non-volatile memory
- Communications
- Remote Inputs: Pump Ready, Inject Hold
- Outputs Pump Stop, Autosampler Ready, Inject, Gradient Start,
Four timed-event outputs
- SpectraNETIRS-232 port
- Ambient
Environment: 10° - 40°C, 5 - 95% relative humidity
- Dimensions:
37cm x 41 cmx 51 cm (HxWxD)