GenTechScientific.com
Contact GenTech
Request Service
Product Search
Home
GC
Mass Spec
HPLC
Other
New Instruments
Parts Department
Vacuum Pumps
Service
About GenTech
Warranty
Financing Options
Equipment List
Specials
Rental
Wanted
Wish List
Download
Glossary
Join Our Mailing List
HPLC Applications Support!!
News and Events

GenTech Newsletter Peak Your Interest

TSP P4000 Pump, AS3000 Autosampler, UV1000 Detector and Software
$6,500*

This system is in good condition and tested at GenTech. Includes P4000 Quaternary Gradient Pump, UV1000 UV/Vis Programmable Detector, AS3000 Autosampler and Data System. This system includes SIX (6) MONTH WARRANTY.

SRI Model 203 Single Channel Chromatography Data System** includes PeakSimple Software to run with Windows 95, 98 Me, XP, and Windows NT 4.0, allows acquisition, integration and display of one detector channel from a GC or LC. Includes two independent timebases, two 0-5VDC DACs, two remote start inputs and built-in AC power supply. Also includes 24-bit serially interfaced acquisition hardware, manuals, FREE lifetime software upgrades and TWO (2) YEAR WARRANTY.

Does not include computer - requires Win 95 or newer.

**GenTech is a distributor of new SRI instruments.

*All prices are in U.S. dollars and do not include shipping, handling and installation. International Cooperating Organizations

P4000 Specifications:

  • Pump Design: Dual in-line piston, pulseless design. Micro-stepped motor control. Floating piston bayonet-mounted heads. Patented ceramic check valves.
  • Flow accuracy: ±0.5% at 1 ml/min with water, after liquid end calibration.
  • Flow precision: <0.2% RSD
  • Flow Range: 0.01 to 10 ml/min standard. Settable in 0.01 ml/min increments.
  • Composition Repeatability: 0.2% RSD
  • Gradient Linearity: ±0.5% from 10-90% composition
  • Maximum Pressure: 6000 psi, 420 bar, 42MPa with standard heads
  • Wetted Surfaces: Stainless steel or PEEK, titanium, ceramic, sapphire, Teflon, Tefzel, and polyethylene
  • Pressure Pulsation: <2% amplitude; <1% typical at 1ml/min water or methanol at >500 psi
  • Delay Volume: <0.6ml
  • Compressibility Compensation: Automatic
  • Shutdown File: Protected in non-volatile memory
  • Flow Stability Test: Pump flow diagnostic to verify proper pump performance
  • Diagnostics: Diagnostic tests to verify proper electrical and mechanical operation
  • Communications: Hardwire external events connector. Run and Stop remote inputs; Ready, Run, Timed Event and Analog Pressure outputs. SCM400 degas communication port.
  • Ambient Environment: 10-40°C, 5-95% relative humidity, noncondensing.

Back to top


UV1000 Specifications:

  • Wavelength Ranges: D2 lamp: 190 to 380 nm, W lamp: 366 to 800 nm
  • Lamp: D2
  • Wavelength Accuracy: ± 1.0 nm
  • Wavelength Precision: <0.01 nm
  • Bandwidth: 6 nm
  • Range Selections: 3.0, 2.0, 1.0, 0.5, 0.2, 0.1, 0.05, 0.02, 0.01, 0.005, 0.002, 0.001, 0.0005 AUFS
  • Absorbance Range: 0.0005 to 3.0 AUFS
  • Absorance Linearity @ 254 nm: 3.0 AUFS
  • Communications:
    - Romote Inputs: Run, Stop, and Zero
    - Romote Output: Ready

AS3000 Specifications:

  • Vial capacity:
    - 120 vials in three removable trays
    - 105 vials with tray temperature control
  • Variable-Volume:
    - Injection Precision: <0.5 % RSD @ 10 pL or greater
    - Injection Volume: 0.1 - 100 pL injection standard (250 uL syringe) up to 1000 uL injections with larger loops and syringes
  • Fixed-Loop:
    - Injection Precision: <0.5% RSD @ 10 uL or greater
    - Injection Volume: 20 uL standard (250 uL syringe) 1000 uL injections with larger loops and syringes
  • Sample Carryover:
    - <0.0 I% at 300 gL flush volume
    - 5 mL flush volumes can be set
  • Minimum Sample Volume: 1 uL can be injected from 5 uL with an end-port needle
  • Needle Height: Programmable in 0.1 mm increments
  • Method Files: Protected in non-volatile memory
  • Communications
    - Remote Inputs: Pump Ready, Inject Hold
    - Outputs Pump Stop, Autosampler Ready, Inject, Gradient Start, Four timed-event outputs
    - SpectraNETIRS-232 port
  • Ambient Environment: 10° - 40°C, 5 - 95% relative humidity
  • Dimensions: 37cm x 41 cmx 51 cm (HxWxD)

GenTech Scientific, TSP P4000 Pump, AS3000 Autosampler, UV1000 Detector and Software
Terms & Conditions
|   Site Map   |
Useful Links
GenTech Scientific, Inc.
23 Mill Street Arcade, NY 14009
Phone: (585) 492-1068
Fax: (585) 492-0383
E-Mail:
sales@GenTechScientific.com

© 2005 GenTech Scientific, Inc.
All prices subject to change without prior notice. Designated trademarks and brands are the property of their respective owners. Please send comments or questions to the
Webmaster.