Contact GenTech
|
Request Service
|
|
Home |
GC |
Mass
Spec |
HPLC |
Other |
New
Instruments |
Parts
Department |
Vacuum
Pumps |
Service |
|
|
|
Waters
2790 Alliance HPLC and 486 Tunable Absorbance
Detector
$21,900*
This
Waters 2790 Alliance HPLC is an integrated solvent
and sample management platform which combines two traditional
high-performance liquid chromatography (HPLC) components:
a solvent management system and a sample management system.
The
Waters 486 is a single-channel tunable ultraviolet/visible
detector designed for high performance liquid chromatography
applications. It can operate as a stand-alone unit or with
other Waters system modules. The Waters 486 provides
a usable light intensity over the wavelength range of 190-600
nm.
This
system is in excellent condition and tested at Gentech.
NINETY
(90) DAY WARRANTY and PeakSimple
Data System included.
The
NEW data system includes PeakSimple Software
to run with Windows 95, 98, Me, XP, and Windows NT 4.0.
It allows acquisition, integration and display of one detector
channel from a GC or LC. Includes two independent timebases,
two 0-5VDC DACs, two remote start inputs and built-in AC
power supply. Also includes 24-bit serially interfaced acquisition
hardware, manuals, FREE lifetime software upgrades
and a TWO (2) YEAR WARRANTY.
Does not include computer or monitor - requires Win 95 or
newer.
**GenTech is a distributor of new SRI instruments.
*All
prices are in U.S. dollars and do not include shipping,
handling and installation. International
Cooperating Organizations
Back
to Waters HPLC Systems
2790 Specifications
486 Specifications

|
|

|
2790
Specifications:
|
Physical
Specifications
|
- Height:
22.5 in. (57 cm)
- Depth:
23.5 in. (60 cm)
- Width:
23 in. (58 cm)
- Weight:
136 lb. (62 kg)
- Wetted
Surface Materials: 316 stainless steel, UHMWPE, sapphire,
ruby, Tefzel® (ETFE), Teflon® (FEP and PTFE), PEEK,
Fluoroloy G, Fluoroloy–08R
|
|
Environmental
Specifications
|
- Operating
Temperature 4 to 40° C
- Relative
Humidity 20 to 80%, noncondensing
- Acoustic
Noise <65 dB(A)
|
|
Solvent
Management System Specifications
|
- Number
of Solvents: One to four, three with vacuum degas
- Solvent
Conditioning:
Vacuum degas, three solvents plus purge solvent
- Typical
Operating Flow Rate Range:
0.050 to 5.000 mL/min in 0.001-mL/min increments
-
Programmable Flow Rate Range:
0.000 and 0.010 to 10.000 mL/min in 0.001-mL/min increments
- Compressibility
Compensation:
Automatic and continuous
- System
Delay Volume: <400 µL, independent of backpressure,
1 mL/min
- Plunger
Seal Wash: Integral, active, programmable
- Gradient
Profiles: Eleven (11) gradient curves [including linear,
step (2 curves), concave (4 curves), and convex (4 curves)]
- Dry
Prime/Wet Prime:
Automatic, front panel control
- Flow
Ramping:
Time (0.01 to 30.00 min in 0.01-min increments) to reach
maximum flow rate
- Maximum
Operating Pressure: 5000 psi (345 bar) at 0.010 to 3.000
mL/min; Programmable upper and lower limits
- Composition
Range: 0.0 to 100.0% in 0.1% increments
- Composition
Accuracy: ±0.5% absolute, independent of backpressure
(Proportioning Valve Pair Test [degassed methanol: methanol/propylparaben,
2 mL/min, 257 nm])
- A
Composition Precision: <=0.15% RSD o r<=0.02 min
SD, whichever is greater, based on retention time. (Degassed
60% methanol:40% water Dial-a-Mix, 1 mL/min, six replicates,
phenone mix, 257 nm)
- Flow
Precision:
<=0.075% RSD or <=0.02 min SD, whichever is greater,
based on retention time (N = 6) or volumetric measures (0.200
to 5.000 mL/min), isocratic premix
- Flow
Accuracy: <=1% or 10 µL/min, whichever is greater,
(0.200 to 5.000 mL/ min), degassed methanol, at 600 psi
backpressure
|
|
Sample
Management System Specifications
|
- Number
of Sample Plates: Total of four plates:
- Microtiter plate – 96- or 384-well
- Vial plate – 2.0-mL vial (48)
- Tube plate – 0.5-mL microcentrifuge tube (48) or 1.5-mL
microcentrifuge tube (24)
- Open access plate – 2.0-mL vial (24 or 48)
- Sample
Temperature Control: 4 to 40° C, programmable in 1°
C increments
- Maximum
Sample Capacity: 1536
in four 384-well plates
- Number
of Sample Injections: 1 to 99 injections per sample
- Sample
Delivery Precision: <0.3% RSD, full loop 50 µL. (Default
wash/purge conditions, degassed 60% methanol: 40% water
Dial-a-Mix, 1 mL/min, six replicates, paraben mix, 257 nm)
- Sample
Volume Linearity: >0.999% correlation, 5 to 20 µL, partial
fill in 50-µL loop, 3-µL pre- and post-sample air gaps (Default
wash/purge conditions, degassed 60% methanol:40% water Dial-a-Mix,
1 mL/min, six replicates, paraben mix, 257 nm)
- Needle
Wash Solvents:
Two: wash (strong solvent) and purge (sample- compatible)
solvent A
- Sample
Carryover: <0.01% or <2.5 nL (default wash/purge volumes),
whichever is greater. (Blank injection, 25 µL, 60% methanol:40%
water, after six replicates, 25 µL propylparaben, 1 g/L,
257 nm)
|
|
Instrument
Control Specifications
|
- Parallel
Sample Processing: User-programmable next-sample aspiration
and loop fill, column equilibration, just-in-time gradient
delivery
- Advanced
Operations: Auto addition, sample pooling, open access,
priority samples
- Column
Heater: 20° C (5° C above ambient) to 60° C, in 1° C
increments
|
|
|
|
486
Specifications:
|
|
Operational
Specifications
|
- Wavelength
range (single, fixed wavelength): 190 to 600 nm
- Wavelength
accuracy: ± 2 nm
- Wavelength
repeatability: ± 0.25 nm
- Noise:
± 1.0 x 10-5 AU, 1 second filter setting, 210 to 280 nm)
dry cell
- Drift:
- 1.0 x 10-4 AU per °C (after warm-up) - 1.0 x 10-4 AU per
hour (after warm-up)
- Sensitivity
Setting Range: 0.001 to 2.0 AUFS (under software control)
Filter Setting
- Range:
0.1 to 5.0 seconds (under software control) Bandwidth: 8
nm
|
|
Optical
Component Specifications
|
- Lamp
Source: Deuterium arc lamp
- Flow
cell:
Dual beam Taper-Cell design
- Path
length: 10 mm (standard, analytical)
- Cell
volume: 8 ul (standard, analytical)
- Pressure
limit: 1000
psi
- Materials:
316 stainless steel, Dynasil Suprasil II, Teflon
|
|
Environmental
Specifications
|
- Operating
temperature: 15
to 32.2 °C
- Operating
humidity: 20 to 80%, non-condensing
- Shipping
and storage temperature: -40° to 65 °C
- Shipping
and storage humidity: 20
to 80% non-condensing
|
Back
to Top
Waters 2790 Alliance HPLC and 486 Tunable Absorbance Detector
|
|