Series
I Isocratic System*
The
Series I Isocratic System is a cost-effective
HPLC unit. The instrument is equipped with a high-pressure
(2500-psi) isocratic pump, manual injection valve, and a fixed-wavelength
UV detector.
The
Series I Isocratic System is well suited
for chemistry education applications as well as dedicated
industrial processes or quality control. Laboratories with
multiple samples for the same analysis can now set up dedicated
HPLC instruments for a given application, eliminating the
need for constantly reconfiguring more expensive equipment
for different processes. R&D laboratories responsible for
method development can transfer a method to this simple system
for reduced operating costs in the plant.
The
system includes a 254 nm detector
and ONE (1) YEAR WARRANTY.
Optional wavelength kits for 214 nm, 229 nm, 280 nm, 350 nm,
370 nm, or the visible range.
| Series
I Isocratic System (Stainless Steel) -
$4,592 |
 |
| Series
I Isocratic System (Bioclean-Peek)
- $5,142 |
 |
Series
I Isocratic System
brochure
*All
prices are in U.S. dollars and do not include shipping, handling
and installation. International
Cooperating Organizations
Back
to New HPLC


| The
Series I Isocratic System comes with the following standard
features: |
-
HPLC pump with Pulse damper
-
Pressure monitoring capability
-
Prime-purge valve; self-flush feature
-
Injector valve with sample port
-
Fixed-wavelength detector, 254 nm
-
Inlet lines with filters, self-flush tubing
-
Accessory kit
|
| Specifications |
|
Series
I Pump
|
| Rated
Pressure |
2500
psi |
| Flow
Rates |
0.01 to 9.99 mL/min. |
| Accuracy
|
2%
|
| Pulsation
|
2%
peak-to peak at 1000 psi,1 mL/min. with LO-Pulse. pulse
damper in line |
| Flow
Precision |
0.5% |
| RemoteControl
|
RS-232
and run/stop |
| Features
|
Prime-purge
valve, self-flush, Pulse damper |
| Power
|
115,
230 Vac, 50/60 Hz |
| Dimensions
|
6.4"
H x 8" W x 14.5" D 16 x 20 x 36.5 cm |
| Weight
|
19
lbs. (7.5 kg) |
|
Fixed
Wavelength Detector
|
| Wavelength
|
254
nm Hg line; other wavelength options on request
|
| Bandwidth
|
<0.1
nm at ½ height |
| Std.
flow cell |
10
mm path length with 18 uL volume, 0.010" ID X 0.063" OD
|
| Noise
and Drift |
<
±1 x10-4 AU (254nm, over 30 min. period, peak-to-peak,
1.0 sec rise time) with std. flow cell at constant temperature
|
| Input/Output
|
RS-232
computer I/O; Injection input (event or run); Auto-zero
input; one analog integrator or chart recorder output,
(voltage range default 1.0 V/AU); selectable analog range
outputs of 4.0, 2.0, 1.0, 0.5, 0.2, 0.1, 0.05, 0.01, 0.005,
0.002, 0.001, 0.0005 AU/V with voltage range of ±
4 V at any scale |
| Dimensions
|
6.6"
H x 9.4" W x 15" D (17 x 24 x 38 cm) |
| Weight
|
12
lbs. (5.5 kg) |
|