BRAND NEW B2300 Binary Gradient System with Model 500 Detector*

The B2300 Binary Gradient System features a binary pump, UV detector, and EZStart software. For reproducible mixing, a static mixer forms part of the high-pressure binary gradient mixing kit. Manual injection valve with a 20 µL loop, injector bracket, column holder, nuts, ferrules, and tubing complete the system.

The Model 500 UV/VIS Detector features high sensitivity with selectable absorbance ranges from 0.0005 to 2.0 AUFS. A second-order Bessel filter, fiber optics, and proprietary circuits ensure low-noise, low-drift performance.

Includes B2300 Binary Gradient Pump, Manual injection valve, Model 500 UV/VIS Detector, EZ Start software, and ONE (1) YEAR WARRANTY.

B2300 Binary Gradient System with Model 500 Detector - $17,541
(Stainless Steel)
B2300 Binary Gradient System with Model 500 Detector Stainless Steel
B2300 Binary Gradient System with Model 500 Detector- $17,937
(Bioclean-Peek)
B2300 Binary Gradient System with Model 500 Detector (Bioclean-Peek)

B2300 Binary Gradient System brochure

*All prices are in U.S. dollars and do not include shipping, handling and installation. International Cooperating Organizations

Back to New HPLC

GenTech Certified: 1-Year Warranty on Used Lab Equipment

 

BRAND NEW B2300 Binary Gradient System with Model 500 Detector (Stainless Steel)

Specifications
Range UV, 190-380 nm (deuterium lamp) Visible, 366-800 nm (optional tungsten lamp)
Optical Design Concave holographic grating monochromator with dual-beam optics
Bandwidth 6 nm
Wavelength ±1nm
Accuracy Wavelength ±0.1 nm
Precision Noise < ±1 x 10-5 AU @254 nm, 1-s rise time (D2 lamp); < ±1 x 10-5 AU @546 nm, 1-s rise time (W lamp)
Drift 2 x 10-4 AU/hr. after warm-up
Absorbance range 0.0005 to 2.0 AUFS (12 settings)
Integrator output 1 V/AU
Recorder outputs 10 mV, 100 mV, 1V
Rise times 0.1, 0.3, 1.0, or 3.0 seconds
Dimensions 25 cm x 17 cm x 34 cm
(9.8" x 6.7" x 14.2") (W x H x L)
Weight 20 lbs. (9.1 kg)
Power 100, 110, 220/240 Vac;
50/60 Hz; 125 W