BRAND NEW B2300 Binary Gradient System with Model 525 Detector *

The B2300 Binary Gradient System features a binary pump, UV detector, and EZStart software. For reproducible mixing, a static mixer forms part of the high-pressure binary gradient mixing kit. Manual injection valve with a 20 µL loop, injector bracket, column holder, nuts, ferrules, and tubing complete the system.

The Model 525 is a full-featured dual-wavelength programmable detector that utilizes theoptical design. In addition, the Model 525 offers spectral scanning, multiple method file storage, queue feature for file linking, and more. A prealigned deuterium lamp is included with all three detectors. A tungsten lamp is included with the Model 525.

Includes B2300 Binary Gradient Pump, Manual injection valve, Model 525 Variable Dual Wavelength detector, EZ Start software, and ONE (1) YEAR WARRANTY.

B2300 Binary Gradient System with Model 525 Detector - $22,515
(Stainless Steel)
BRAND NEW B2300 Binary Gradient System with Model 525 Detector (Stainless Steel)
B2300 Binary Gradient System with Model 525 Detector- $22,614
(Bioclean-Peek)
B2300 Binary Gradient System with Model 525 Detector (Bioclean-Peek)

B2300 Binary Gradient System brochure

*All prices are in U.S. dollars and do not include shipping, handling and installation. International Cooperating Organizations

Back to New HPLC

GenTech Certified: 1-Year Warranty on Used Lab Equipment

 

BRAND NEW B2300 Binary Gradient System with Model 525 Detector (Stainless Steel)

Features
  • Optimized motor control algorithm
  • High-speed motor drive
  • Real-time spectra Display lMAX
  • DevelopFile™ Six method files Automatic lamp startup/shutdown Programmable autozero
  • Autoscan
Specifications
Optical design Concave holographic grating monochromator, with dual beam optics; pre-aligned lamps
Noise <±1.0 x 10-5 AU @254 nm, 1.0 s rise time;
<±2.5 x 10-5 AU @254 and 280 nm, 1.0 s rise time, dualwavelength mode
Drift <2 x 10-4 AU/hr. after warm-up @ 254 nm
Wavelength range Deuterium (D2) lamp: 190-365 nm
Tungsten (W) lamp: 366-800 nm
Dual Wavelength: 190-450 nm, or, 366-800 nm
Lamp(s) D2 and W standard
Wavelength accuracy ±1.0 nm
Wavelength precision ±0.1 nm
Spectral bandwidth 6 nm
Absorbance range 0.0005-3.0 AUFS
Absorbance linearity >1% to 2.0 AU @254 nm
Remote inputs Run, Stop, Zero
Output flags Ready, Accessory Relay
Analog outputs both range-selectable over entire absorbance range
Ambient Environment 10 to 40° C; 5% to 95% relative humidity, noncondensing
Dimensions 17 cm x 30 cm x 41 cm (HxWxL)
Weight 14kg(31lbs.)
BRAND NEW B2300 Binary Gradient System with Model 525 Detector Stainless Steel