Shimadzu
GC-2010 with Single Wide Bore and Single Valco TCD
$8,800 *
System
Includes:
- Single
Wide Bore Injector
- Single
Valco TCD
- Fast
Oven Cooling Option
- Automatic
Pressure Control (APC)
- 110V/60Hz
- User
Manual
- ONE
(1) YEAR WARRANTY
Available
Options:
*All
prices are in U.S. dollars and do not include shipping, handling
and installation. International
Cooperating Organizations
|


Specifications
|
Column
Oven |
| Temperature
Range |
(Ambient
+ 4°C) ~ 450°C (using LCO2 gas: -50°C - 450°C) |
| Inner
Dimensions and Volume |
280
(W) x 280 (H) x 175 (D) mm, 13.7L |
| Temperature
accuracy |
±1%
of the set temperature in Kelvin unit (calibration at
0.01°C increments) |
| Temperature
Variation Coefficient |
0.01°C/°C |
| Temperature
Program Steps |
Up
to 20 (cooling program possible) |
| Programmed
rate setting range |
-250°C
~ 250°C/min |
| Total
time for all steps |
9999.99
minutes max. |
|
Injection
Ports |
| Temperature
Range |
Up
to 400°C |
| Heating
Settings |
1°C
steps |
| No.
of units installed simultaneously |
Up
to 3 units |
| Sample
injection unit types |
Split/splitless
injection is standard
Direct (without split) injection unit (option)
On-column/PTV (programmable temperature vaporizer)injection
unit (option) |
|
Flow
Control Unit |
| Advanced
Flow Controller (AFC) |
| Split/splitles
injection mode and direct injection mode |
Pressure
range: 0-970kPa |
| Programmable
Steps |
7
(Negative pressure step is available) |
| Programmed
Rate Setting Range |
-400
~ 400kPa/min |
| Split
Ratio Range |
0
- 9999.9 |
| Mass
Flow Rate Setting Range |
0
- 1200mL/min |
| Constant
Linear Velocity |
Maintains
optimum separation at all times |
|
Available
Optional Accessories |
| AOC-20i
Auto Injector |
Direct
injection, PTV/LVI, 1 - 250 uL syringes, ambient headspace |
| AOC-20s
Auto Sampler |
150
1.5mL vials or 96 4mL vials and barcode reader |
| Leap
Combi-Pal Autosampler |
SPME,
headspace and micro-titer plate sampling capability |
| PY2020D
Pyrolyzer |
Single
or double shot includes autosampler |
| |
|
|
Detectors |
| Four
detectors can be installed simultaneously and individually
temperature controlled. Detector gas is electronically
controlled by APC (Advanced Pressure Control) |
| Detector
Type(s) |
FID,
TCD, ECD, FPD, FTD |
| Flame
Ionization Detector (FID) |
| Temperature
Range |
450°C
max. |
| Minimum
detected quantity |
3pgC/s
(Dodecane) |
| Dynamic
Range |
107 |
| Thermal
Conductivity Detector (TCD) |
| Temperature
Range |
400°C
max. |
| Dynamic
Range |
105 |
| Sensitivity |
20,000
mV - mL/mg (Decane) |
| Electron
Capture Detector (ECD) |
| Temperature
Range |
350°C
max. |
| Minimum
detected quantity |
8fg/s
|
| Dynamic
Range |
104 |
| Flame
Photometric Detector (FPD) |
| Temperature
Range |
350°C
max. |
| Dynamic
Range |
P:
104
S: 103 |
| Minimum
detected quantity |
P:
0.2pgP/s (tributyl phosphate)
S: 4pgS/s (dodecane thiol) |
Flame Thermionic Detector (FTD)
(Two types, one for capillary and one
for packed. The specifications are the same.) |
| Temperature
Range |
450°C
max. |
| Dynamic
Range |
N:
104
P: 104 |
| Minimum
detected quantity |
N:
0.2pgN/s (azobenzene)
P: 0.03pgP/s (malathion) |
| Maximum
of 2 detectors to keep instrument performance |
|
Dimensions,
Weight, Power Requirements (GC main unit) |
| Dimensions |
515
(W) x 440 (H) x 530 (D) mm |
| Weight |
30
kg (FID model) |
| Power
Requirements |
AC100V/120V
230V
1800VA (Normal oven type) or
2600VA (High power oven type), 50/60Hz |
|
GenTech Scientific, Shimadzu GC-2010 with Single Wide Bore and Single Valco TCD
|
|